A veteran engineer with 30 years of experience explains the YB/T 4001.1 standard, sizing calculations and installation essentials, helping you purchase scientifically and avoid detours.
WhatsApp & E-mail support | Free sizing & quotation
To explain steel grating specification codes, take G323/30/100, one of the most typical models in the industry: 1. In G323/30/100, the leading G indicates that the string is a steel grating model; SG would indicate serrated steel grating, whose bearing bars are evenly covered with identical serrations. 2. In G323/30/100, the first two digits 32 in 323 indicate that the bearing bars are 32 mm wide...

Bearing bar: the main material of steel grating, a uniformly rolled flat bar that carries the load with both ends resting on steel beams. Cross bar: a twisted square bar of square section, welded perpendicular onto the bearing bars to hold them in place. Edge band: a flat bar of the same section as the bearing bars, welded to their ends and used to close edges when banding or cutting openings. Panel length: the overall dimension measured parallel to the bearing bars...

Should stair treads be fixed with screws or by welding? Bolted fixing requires a drilled rear side plate, while direct welding needs no thickened side plate. Treads are usually hot-dip galvanized or spray-painted; spray-painted treads need an anti-rust primer before the top coat to achieve long-term corrosion protection. Galvanized steel grating treads are a stair application of steel grating; by fixing method they are generally welded...

Steel cover plates can be fixed either by welding or with installation clips. Welding gives a permanent fix that will not work loose: at each corner of the panel, on one edge bar, use a fillet weld not less than 20mm long and 3mm high. Installation clips do not damage the hot-dip zinc coating and are easy to remove; at least 4 sets are needed per panel, and the number increases with panel length. The method omits the lower clip and...

1. The clear opening of steel grating used on work platforms or walkways must not allow a 35mm diameter sphere to fall through, to avoid the risk of objects dropping through the grating gaps. 2. For steel grating used on platforms and walkways above occupied areas, on emergency escape routes, and for stair treads and landings, the clear opening must not allow a 20mm diameter sphere to fall through; otherwise other suitable measures must ensure the same safety level...